Product — Facility Database System

Document your entire facility — from cable hub to data center.

The Facility Database System manages full-scale infrastructure documentation: cable hubs, cable headends, distribution nodes, colocation facilities, data centers, and IT server rooms — all in one structured database. Trace any circuit hop-by-hop, auto-calculate facility load, and know exactly what's patched where before you roll a truck or dispatch a crew.

🏢
Circuit Trace — Live Demo

From headend device to customer — hop by hop

Click any device port in the Facility Database and trace the full circuit path outward. Every patch and preterm connection is shown in sequence — with the facility, rack, and port label at each hop.

Circuit trace — Customer: 4218 Rozzelles Ferry Rd, Charlotte NC
📡
CMTS Slot 4 / Port 12
Hub A — Main Hub, Rack 2 → Patch panel PP-A04 port 12
🔌
Patch Panel PP-A04 port 12
Hub A — Main Hub, Rack 2 → Preterm Block PTB-07 position 24
🔗
Preterm Block PTB-07 position 24
Hub A — Main Hub → Fiber 37, Buffer Tube 4 → Node Hub B
🔌
Preterm Block PTB-02 position 09
Hub B — Distribution Node, Rack 1 → Amplifier AMP-12 port A
🏠
Customer: 4218 Rozzelles Ferry Rd
Drop node 14 → tap port 3 → coax drop

Everything to document and maintain your plant

🏗️

Full facility hierarchy

Facilities → cages → racks → devices → ports, all linked. Cable hub, distribution node, colo suite, or data center floor — the same model handles all of them.

🔄

End-to-end circuit tracing

Trace any circuit from headend or core switch out to the OCEF cabinet — through patch panels, cross-connects, and preterm blocks — hop by hop, right up to where it hands off to the outside plant.

📊

Hub & data center load calc

Auto-calculate facility load: power draw per rack, HVAC capacity, generator runtime, battery plant discharge, and DC bus loading. Flags headroom issues before they become outages.

Power density tracking

Rack-level kW tracking, PDU and breaker panel assignments, UPS bypass state, and power path from utility feed to device. Built for data center power management as well as cable plant DC systems.

📋

Port-level inventory

Patch panels, preterm blocks, OCEF cabinets, cross-connect frames — all documented with port occupancy, cable label, connection type, and status.

🔍

Search across all sites

Find any device, port, circuit, or customer connection across all facilities by partial name. Results return with full hierarchy context — site, cage, rack, port.

Hub Utilization

Real-time auto-calculations for every hub

Enter your facility equipment and the Facility Database calculates load, capacity, and headroom automatically. Spot issues before they become outages.

⚡ Power & HVAC

Total load14,280 W
Capacity20,000 W
Headroom28.6%
BTU/hr load48,720 BTU
HVAC capacity51,200 BTU ⚠

🔋 DC Plant & Generator

DC load840 A @ 48V
Battery strings4 × 200 Ah
Runtime (no gen)5.7 hr
Generator45 kW diesel
Fuel at 75% load1.8 gal/hr

Don't have the data yet? We'll get it for you.

🔍

Fully audited and built, ready to hand off

We send an engineer to your facility — cable hub, headend, distribution node, colo, data center, or IT server room. Every rack, device, port, circuit connection, and cross-connect is documented against your as-built records and loaded directly into the Facility Database System. You get a clean, verified, importable data set — not a spreadsheet you have to interpret.

One-time engagement. Per-site pricing based on facility count, rack density, and scope.

Request Audit Pricing

Try it live — no account required

The demo loads a real cable hub (Harrisburg, NC) with fully populated racks, devices, circuits, and preterm assignments. Trace a circuit, explore the hub utilization dashboard, and look up preterm connections. Changes are session-only and reset automatically.

Launch Live Demo → Request a Guided Demo